Calculators / 555 Timer Calculator
555 Timer Calculator
Analyze monostable pulses and astable oscillators, reverse-design timing components, and plot the ideal output timing.
Inputs
Try the prefilled example, or enter your own values.
Result
Calculate to see the result and worked steps. Changing an input clears the previous result.
How to use
- Choose a one-shot or oscillator and analysis or reverse design.
- Use kΩ and nF as labelled. A classic astable reverse design requires output-high duty strictly above 50% and below 100%.
- Compare theoretical and selected standard components, then read the actual timing and waveform. Check the specific timer datasheet for current, leakage and frequency limits.
Formula and assumptions
Monostable: t = ln(3) RA C ≈ 1.1 RA C. Astable: tH = ln(2)(RA + RB)C; tL = ln(2) RB C; f = 1/(tH + tL); Dhigh = tH/(tH + tL).
Classic 555 timing connections with ideal 1/3 and 2/3 supply thresholds. Reverse design selects each component independently from E24; actual timing is recalculated. Supports 100 Ω–10 MΩ and 1 pF–1 F mathematically; these are not guaranteed practical timing or discharge-current limits. Waveforms show normalized logic, not actual output voltage.
Sources
Worked example
For an astable with RA = 1 kΩ, RB = 10 kΩ and C = 100 nF, high time is 762.46 µs, low time 693.15 µs, frequency 687.00 Hz and output-high duty 52.38%.
Common mistakes
A classic two-resistor astable cannot produce 50% or lower high duty with positive RA. Normalized high/low levels do not predict rail swing, drive current or startup transients.